V4: Emitted power and pulse width
From EG-CLIMET
Contents |
1 Purpose
This procedure allows to measure the emitted power and the pulse width. The emitted power is a determining factor for the measurement range and it should always be within the tolerances around the nominal value.
2 Remarks
- This procedure contains measurements at high power radiation. Experience and careful handling is absolutely necessary!
- The procedure has been tested for a lap-3000. For other models, it is referred to the documentation.
- This procedure can also be found in the Factory Acceptance Test.
3 Material
- Male and female SMA, BNC and N adapters
- 50Ω loads
- Attenuators (for example: 20 dB, 0 - 2 GHz, 5 kW peak power, 80 W average power)
- Directional coupler (for example: 10 kW peak power, 200 W average power, 950 - 2000 MHz)
- RF cable (type RG58)
- Power meter with power sensor (>30 MHz bandwidth)
4 Procedure
- Connect the the power meter to the wind profiler as illustrated here:Media: SchemaPowerVaisala.png and Media: PicturePowerVaisala.png
- Start acquisition using the following configuration file: Vaisala Configuration File
- Press PAUSE in the acquisition software
- Read the pulse width and the peak power value from the power meter
- Convert the peak power to Watts with this formula: peak power (W) = 10^[peak power (dBm) + attenuator loss - 30 dB]. It shoud be >450 W (lap-3000)
Back to Maintenance Procedures; Go to RWP Maintenance in CWINDE;