D2: Emitted power and pulse width
From EG-CLIMET
Contents |
1 Purpose
This procedure allows to verify the peak power emitted by the amplifier.
2 Remarks
Attention, this procedure includes measurements of high power radiation. Experience and careful handling is absolutely necessary!
3 Material
- Peak power meter with sensor head
- Directional coupler (peak power = 10 kW, average power = 200 W, bandwith = .95 - 2 GHz or equivalent)
- Attenuators (peak power = 5 kW, average power = 10 W, attenation 20 dB or equivalent)
4 Procedure
- Stop acquisition.
- Configure a one-measurement (vertical) wind cycle with an IPP of 1000 μs and a pulse width of 2500 ns and pulse code = 0
- Calibrate the peak power meter and the probe
- Insert the directional coupler between the amplifier output and the circulator (Media:PicturePowerDegreane.png)
- Add sufficiently attenuators coupling output of the coupler and the peak power meter
- Start acquisition
- Measure the emitted peak power taking into account the total attenuation
Go to Maintenance Procedures; Go to RWP Maintenance in CWINDE;